DEHNguard -
Flexible surge protection for every application

The DEHNguard family offers powerful Type 2 + 3 surge protection for modern power distribution. With innovative connection options – whether push-in double terminals or double screw clamps – the respective series adapts flexibly to your installation requirements and enables efficient and safe wiring. 

With push-in or screw connection
For stub wiring or feed-through wiring
For TT, TN-S or TN-C systems
dehn

Two series for maximum flexibility during installation

Thanks to variable connection technologies and compact design, there are two versions to choose from:

DEHNguard MD

DEHNguard MP

Versatile wiring with double screw clamp 

Convenient connection with push-in double terminal 

  • Robust screw technology for secure connections 
  • For one conductor up to 35 mm² or two conductors up to 16 mm² each
  • Connections at the front for simple visual inspection and quick installation
  • For conductor cross-sections up to 10 mm² 

Benefits at a glance

01
Space-saving feed-through wiring

saves space in the switchgear cabinet and facilitates retrofitting. 

Simple to comply with cable lengths as per IEC 60364-5-53. 

02
System availability with ACI variants

eliminates the need for an additional back‑up fuse thanks to innovative Advanced Circuit Interruption (ACI) technology.

03
Easy maintenance

plug-in modules can be quickly replaced in the event of a fault.   

The DEHNguard product family at a glance

Close-up of an electrical panel with multiple red surge protectors and various colored wires connected to them.
DEHNguard MP

Easy. Quick. Safe. DEHNguard MP with push-in double terminals saves space and installation time. The pluggable connections at the front enable convenient feed-through wiring – without a terminal block. 

dehn
DEHNguard MD

The integrated double screw clamp allows either 1 x 35 mm² or 2 x 16 mm² (copper) cores to be securely connected. This enables a standard-compliant and space-saving installation that saves both time and additional terminals.

DEHNguard ACI in application
DEHNguard MP ACI

More safety, less effort. The DEHNguard MP ACI provides reliable protection without the need for an additional backup fuse – thanks to integrated ACI technology. And impresses with simple and space-saving installation. 

943440_dehnguard_md_aci_800x800.webp
DEHNguard MD ACI

DEHNguard MD ACI combines reliable protection without an additional backup fuse - thanks to integrated ACI technology - with maximum flexibility in installation. 

Selection made easy

Which DEHNguard solution best suits your requirements? This table will help you select the right version based on connection type, application recommendation and systems. 

 DEHNguard MP
(push-in)
DEHNguard MD
(double screw)
DEHNguard MP ACI 
(push-in)
DEHNguard MD ACI 
(double screw)
Installation requirements    
Parallel connection
Feed-through wiring
Up to max. 
40 A / 10 mm²

Up to max. 
63 A / 16 mm²
Advanced Circuit Interruption (ACI) technology
Push-in connection technology
Screw connection
Recommended field of application    
Control cabinet (≤ 40 A)
Residential building sub-distribution
board (≤ 40 A)
Industrial sub-distribution board 
(≤ 125 A)
Industrial main distribution board
(≥  125 A; without additional 
back-up fuse)

DEHNguard – Quality and innovation for more than 30 years

dehn
01
1993

DEHNguard 275

dehn
02
1994 | 2000

DEHNguard T single/multi-pole

dehn
03
2003 | 2009

DEHNguard YPV | DEHNguard YPV SCI

dehn
04
2010

DEHNguard CI

dehn
05
2018

DEHNguard ACI

dehn
06
2022

DEHNguard push-in

dehn
07
2025

DEHNguard double screw clamp

Three-stage protection concept

A Type 2 surge arrester (also known as SPD Type 2 for surge protective devices) is typically used in sub-distribution boards in electrical installations. It protects electrical and electronic devices from transient overvoltages that can be caused by switching operations in the network or indirect lightning strikes. Type 2 SPDs reduce overvoltages to a level that is safe for terminal equipment, with a typical discharge capacity of 5–20 kA (8/20 µs) per pole.

Type 2 arresters are an important part of an effective surge protection concept, in which the incoming energy is gradually reduced to a low level that is harmless to terminal equipment:

  • Stage 1 represents type-1 lightning current arresters / combined arresters at the entrance point into the building (lightning equipotential bonding).
  • Stage 2 is type-2 surge arresters usually installed in the downstream sub-distribution boards.
  • Stage 3 includes type-3 surge arresters, which can be installed directly at the terminal device or in socket outlets.

Interaction of the individual protection stages ensures the best possible protective effect. To this end, the relevant arresters must be energy coordinated according to IEC 60364-5-53 clause 534.

Downloads

Any questions?

Write us a message.

I agree to the processing of my personal data in accordance with the Data Privacy Statement. Take me to the Data Privacy Statement.

 
Here you will find all information about the processing of your personal data.
CAPTCHA
This question tests whether you are human or a computer and prevents automated spam submissions.